DESCRIPTIONS:

  • Pneumatically driven and electronically controlled
    ventilation

  • Suitable for children and adults

  • Easy control of user interface by touch screen &
    navigator wheel

  • Sensitive adjustable flow trigger and pressure trigger
    Lung mechanics monitoring and flow loops

  • 15”TFT LCD color screen

  • Synchronized nebulizer

  • Inspiratory and expiratory hold

  • Manual inspiration

  • Smart suction

  • Built-in battery (≥1hour) or optional extended
    batteries (≥2hours operation)

  • Easy to position ergonomic Trolley available with
    lockable drawer and auxiliary AC outlets

  • Easily removeable and sterilizeable exhalation
    valve module

Modes of Ventilation

  • Pressure Controlled (PCV), Assist/Control

  • Pressure Regulation Volume Controlled (PRVC),

  • Assist/Control

  • Synchronized Intermittent Mandatory

  • Ventilation, SIMV(VCV) + PSV, SIMV(PCV) + PSV,

  • SIMV(PRVC) + PSV

  • Spontaneous Ventilation (SPONT/CPAP) + PSV

  • Bi Level Ventilation (BIVENT/APRV) + PSV

  • Non-invasive Ventilation (NIV/CPAP + PSV,

  • NIV/PCV)

  • Volume Controlled (VCV), Assist/Control

Parameters and Ranges

  • Tidal volume: 20-2500ml

  • Respiratory rate: 1-120bpm

  • Inspiration time:0.2-9s

  • Inspiratory pause time: 0-4s

  • Tslope : 0-2s

  • FiO2: 21%~100%

  • PEEP: 0-50cmH2O

  • CPAP: 2-20cmH2O

  • Psupport: 0-90cmH2O

  • Pinsp: 5-90cmH2O – USA
    0-100cmH2O – International

  • Esens: 5%-80%

  • Flow patterns: square, decelerating

  • Inspiratory hold

  • Expiratory hold

  • Nebulizer: 30 or 45 minutes

  • Auto tube compensation

  • Compliance compensation

  • Graphical trends

  • Nurse call

Monitoring

  • Pressure values: Pmin, Pplat, Pmean, Ppeak, PEEP

  • Volume/Flow values: VTI, VTE, MV, MVspont, Leak%

  • Loops: Flow – Pressure, Pressure – Volume,

  • Flow – Volume

  • FiO2

  • Optional etCO2

Alarms

  • MV high, MV low, Circuit disconnect, Paw high, Paw low, Continuous airway pressure high, VTi high, fspont high, Tapnea, FiO2 high, FiO2 low, etCO2 high, etCO2 low, Power supply failure, Battery low, Battery exhausted, Air supply failure, O2 supply failure, PEEP low.

Operating Conditions

  • Gas supply: O2, Air, 200kPa -650kPa (29-94PSI)

  • Power supply: 100-240V, 50-60Hz

  • Temperature: 10-40 (Operation)

  • -20-60℃(Storage)

  • Relative humidity: 5-95%, non-condensing
    (Operation)

  • ≤95%, non-condensing (Storage)

  • Atmospheric pressure: 500hPa-1060hPa
    (Operation&Storage)

  • Communication interfaces: RS232, VGA, USB, Rj45

  • Dimensions (H×W×D): 624x774x1410mm

Standards

  • UL/IEC 60601-1, IEC 60601-1-2, IEC 60601-2-12, EN 794-1

​

V8600

Drive mode:

  • Built-in low noise turbine

  • Lifetime over 30,000 hours

  • No request for air compressor

​

Scope of application:

  • ICU, Respiratory Department or Emergency Department

  • For the rescue and therapy of the patient with respiratory insufficiency

  • Other departments for providing respiratory support for the patient.

​

V7600

  • V7600 Offering reliable performance with versatile ventilation modes such as pressure control and CPAP. It helps optimize quality of care and patient comfort, improving patient outcomes. One device addresses diverse ventilation requirements, fully covering various situations, meets the breathing requirements of adult, pediatric and infant patients.

 

  • ApplicationEmergency department, ambulance & intra-hospital transfer

  • Versatile ventilation modes

    • Pressure control & Volume control ventilation

    • Invasive & Non-Invasive ventilation

    • SPONT/PSV,CPAP ventilation

     

  • Enhancement

    • FiOâ‚‚ 40% to 100% continues adjustable

    • Waveform display: Pressure-time & Flow-time

    • Manual breath

    • Inspiration hold

    • Alarm silence

    • Pre-use test

​

​

​

​